Gjenerator emergjenceBGG - Deutschland
EPS-C40 770S
Gjenerator emergjence
BGG - Deutschland
EPS-C40 770S
çmim fiks plus TVSH
194 000 €
viti i prodhimit
2023
Gjendje
I ri
Vendndodhje
Nüziders 

Fotot tregojnë
Shfaq hartën
Të dhëna për makinën
- Përshkrimi i makinës:
- Gjenerator emergjence
- Prodhues:
- BGG - Deutschland
- Model:
- EPS-C40 770S
- Numri i makinës:
- 221055-1
- Viti i prodhimit:
- 2023
- Gjendje:
- i ri
- Funksionalitet:
- plotësisht funksionale
Çmimi & Vendndodhja
çmim fiks plus TVSH
194 000 €
- Vendndodhje:
- Kuhbrückweg 3, 6714 Nüziders, AT

Telefononi
Detaje teknike
- Lloji i rrymës hyrëse:
- Kondicioner ajri
- Tensioni hyrës:
- 400 V
- Lloji i ftohjes:
- ujë
- Gjerësia totale:
- 2 430 mm
- Gjatësia totale:
- 12 080 mm
- Lartësia totale:
- 2 880 mm
- Karburant:
- naftë
- Peshë totale:
- 18 000 kg
- Fuqi e vazhdueshme (e dukshme):
- 770 kVA
- Fuqi e vazhdueshme:
- 616 kW (837,53 HP)
- Shpejtësia rrotulluese (maks.):
- 1 500 rrot/min
- Cilindrada:
- 16 400 cm³
- Kapacitet i rezervuarit të karburantit:
- 9 000 l
- Kapaciteti i rezervuarit:
- 9 000 l
- Fuqi:
- 616 kW (837,53 HP)
- Fuqi nominale (aparante):
- 770 kVA
- Frekuenca e hyrjes:
- 50 Hz
- Pajisje:
- dokumentacion / manual, shpejtësia rrotulluese pafundësisht e ndryshueshme
Detajet e ofertës
- ID e shpalljes:
- A18494271
- Përditësim:
- së fundmi më 23.06.2025
Përshkrim
EPS-C40 770S - 72h Container Emergency Power Supply Unit:
AVAILABLE IMMEDIATELY!!!!
GT770S 770 700 Scania DC16 078A 02 43 400/230V 50Hz-LS
Rated power PRP: 700.0 kVA, 560.0 kW cos Phi = 0.8
Rated power LTP: 770.0 kVA, 616.0 kW cos Phi = 0.8
Reference conditions according to DIN ISO 8528
Speed: 1500 rpm
Design: Stationary
Engine:
Scania DC16 078A 02 43, four-stroke diesel engine, liquid-cooled, crankcase ventilation
returned to the engine block, fuel system with pre-filter, filter, and water separator,
combustion air filter with vacuum indicator, fuel hoses for connection of supply and return lines
with flexible transition. Electric starter,
engine shut-off device, and electronically governed speed regulator.
Rated power: 596.0 kW
Rated speed: 1500 rpm
Cylinders: 8-cylinder V
Displacement: 16,400 cm³
Leroy Somer LSA 49.3 M6
4-pole three-phase synchronous generator
Continuous output: 730.0 kVA at 40°C
Rated voltage: 400V
Rated frequency: 50Hz
Manual engine oil change pump from 700 kVA
Manual pump for emptying the engine oil pan.
Electric engine preheater 1000W up to 700 kVA 1.00 unit
The preheated coolant circulates in the primary cooling circuit of the engine
via convection. Connected with flexible coolant hoses to the engine’s internal cooling circuit,
equipped with shut-off valves for maintenance accessibility.
Coolant recirculation pump ensures safe preheating of the engine.
Walls and ceiling made from pressed steel plate. Derusting and cleaning accomplished by
sandblasting the welded structure. The container is coated inside and out with
marine-grade primers and paints for seawater resistance.
Container 40" HC High Cube Soundproofed
Container ISO 1496-1 for power generation units, external dimensions according to ISO 668.
Wall and roof panels are insulated with self-extinguishing, oil- and water-resistant
sound insulation material, enclosed with glass fibre matting and electro-galvanized coated perforated sheet metal cassettes.
The exhaust silencer is housed in a separate compartment within the container.
Radiant heat is safely discharged vertically with the cooling airflow from the front-mounted radiator.
Air intake openings are installed in the wall surfaces; air exhaust outlet in the roof.
The exhaust outlet of the silencer is protected by an exhaust flap against the ingress of water.
One front side is equipped with double-leaf doors with circumferential sealing and
serves as an inspection opening.
Hsdpfjvyp H Ujx Af Sew
Side personnel doors, with emergency release and circumferential sealing, provide access for
maintenance work.
The silencer and exhaust compartment is also fitted with an access door.
Plant operation is performed externally.
The control system and indicators can be viewed through an inspection window even when the
door of the control panel is closed.
The emergency stop button is protected from damage and mounted in a recessed housing niche.
Cable entry can be made from the side or through the container floor. The floor entry is prepared for
annular space seals DN 150.
40" Container collection tray according to WHG
Oil-tight welded checker plate floor with surrounding upstand, min. 50 mm
And much more…
Special feature: MAINS PARALLEL operation possible!!!
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
AVAILABLE IMMEDIATELY!!!!
GT770S 770 700 Scania DC16 078A 02 43 400/230V 50Hz-LS
Rated power PRP: 700.0 kVA, 560.0 kW cos Phi = 0.8
Rated power LTP: 770.0 kVA, 616.0 kW cos Phi = 0.8
Reference conditions according to DIN ISO 8528
Speed: 1500 rpm
Design: Stationary
Engine:
Scania DC16 078A 02 43, four-stroke diesel engine, liquid-cooled, crankcase ventilation
returned to the engine block, fuel system with pre-filter, filter, and water separator,
combustion air filter with vacuum indicator, fuel hoses for connection of supply and return lines
with flexible transition. Electric starter,
engine shut-off device, and electronically governed speed regulator.
Rated power: 596.0 kW
Rated speed: 1500 rpm
Cylinders: 8-cylinder V
Displacement: 16,400 cm³
Leroy Somer LSA 49.3 M6
4-pole three-phase synchronous generator
Continuous output: 730.0 kVA at 40°C
Rated voltage: 400V
Rated frequency: 50Hz
Manual engine oil change pump from 700 kVA
Manual pump for emptying the engine oil pan.
Electric engine preheater 1000W up to 700 kVA 1.00 unit
The preheated coolant circulates in the primary cooling circuit of the engine
via convection. Connected with flexible coolant hoses to the engine’s internal cooling circuit,
equipped with shut-off valves for maintenance accessibility.
Coolant recirculation pump ensures safe preheating of the engine.
Walls and ceiling made from pressed steel plate. Derusting and cleaning accomplished by
sandblasting the welded structure. The container is coated inside and out with
marine-grade primers and paints for seawater resistance.
Container 40" HC High Cube Soundproofed
Container ISO 1496-1 for power generation units, external dimensions according to ISO 668.
Wall and roof panels are insulated with self-extinguishing, oil- and water-resistant
sound insulation material, enclosed with glass fibre matting and electro-galvanized coated perforated sheet metal cassettes.
The exhaust silencer is housed in a separate compartment within the container.
Radiant heat is safely discharged vertically with the cooling airflow from the front-mounted radiator.
Air intake openings are installed in the wall surfaces; air exhaust outlet in the roof.
The exhaust outlet of the silencer is protected by an exhaust flap against the ingress of water.
One front side is equipped with double-leaf doors with circumferential sealing and
serves as an inspection opening.
Hsdpfjvyp H Ujx Af Sew
Side personnel doors, with emergency release and circumferential sealing, provide access for
maintenance work.
The silencer and exhaust compartment is also fitted with an access door.
Plant operation is performed externally.
The control system and indicators can be viewed through an inspection window even when the
door of the control panel is closed.
The emergency stop button is protected from damage and mounted in a recessed housing niche.
Cable entry can be made from the side or through the container floor. The floor entry is prepared for
annular space seals DN 150.
40" Container collection tray according to WHG
Oil-tight welded checker plate floor with surrounding upstand, min. 50 mm
And much more…
Special feature: MAINS PARALLEL operation possible!!!