AUTOKLAVË STATIKE LAGARDE S/S 4 BLAGARDE
SA
AUTOKLAVË STATIKE LAGARDE S/S 4 B
LAGARDE
SA
Gjendje
I përdorur
Vendndodhje
Lorquí 

Fotot tregojnë
Shfaq hartën
Të dhëna për makinën
- Përshkrimi i makinës:
- AUTOKLAVË STATIKE LAGARDE S/S 4 B
- prodhues:
- LAGARDE
- Model:
- SA
- Gjendje:
- i përdorur
- funksionalitet:
- plotësisht funksionale
Çmimi & Vendndodhja
- Vendndodhje:
- Polígono Industrial de Lorquí Parcela 129, 30564 Lorquí, ES
Telefononi
Detajet e ofertës
- ID e shpalljes:
- A19238281
- Numri i referencës:
- 0000000197561
- përditësim:
- së fundmi më 27.05.2025
Përshkrim
Autoclaves are used for the sterilization of packaged products that need to reach high temperatures (+100ºC) for the elimination or inactivation of pathogenic microorganisms.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
Gusdpfx Abswndplemjh
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
Gusdpfx Abswndplemjh
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Dokumente
Ofrues
Shënim: Regjistrohuni falas ose hyni, për të parë të gjitha informacionet.
I regjistruar që nga: 2024
Dërgo kërkesë
Telefon & Faks
+34 968 6... njoftime
Njoftimi juaj u fshi me sukses
Ndodhi një gabim