Kabineti testues i temperaturës 600 litraWeiss
WT3-600/40 -42°C bis +180°C
Kabineti testues i temperaturës 600 litra
Weiss
WT3-600/40 -42°C bis +180°C
Gjendje
I përdorur
Vendndodhje
Borken 

Të dhëna për makinën
- Përshkrimi i makinës:
- Kabineti testues i temperaturës 600 litra
- Prodhues:
- Weiss
- Gjendje:
- shumë mirë (i përdorur)
Çmimi & Vendndodhja
- Vendndodhje:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A22184752
- Numri i referencës:
- 23956
- Përditësim:
- së fundmi më 23.06.2026
Përshkrim
Here, we offer a Weiss temperature chamber.
Weiss temperature test chamber with S!MCON / 32 control, air-cooled
(Refrigerant converted to R-452A)
Control panel »Touchpanel«
On the »Touchpanel« control panel, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine part, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and test equipment to be placed in the test chamber.
Feedthrough installed as standard
R1: 125 mm
L1: 50 mm
Test chamber volume: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 2500 W
Data for operation:
Test chamber lighting: halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Hodpfxjzga Huj Ahkonr
Rated current: 15 A, Rated power 7.8 kW
Fuse, to be provided by the customer: 16 A, slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front, 1m height: 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Weiss temperature test chamber with S!MCON / 32 control, air-cooled
(Refrigerant converted to R-452A)
Control panel »Touchpanel«
On the »Touchpanel« control panel, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine part, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and test equipment to be placed in the test chamber.
Feedthrough installed as standard
R1: 125 mm
L1: 50 mm
Test chamber volume: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 2500 W
Data for operation:
Test chamber lighting: halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Hodpfxjzga Huj Ahkonr
Rated current: 15 A, Rated power 7.8 kW
Fuse, to be provided by the customer: 16 A, slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front, 1m height: 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Këto njoftime mund t'ju interesojnë edhe ju.
Njoftim i vogël
Borken
1 562 km
Kabineti testues i temperaturës 600 litra
WeissWT3-600/40 -42°C bis +180°C
WeissWT3-600/40 -42°C bis +180°C
Njoftimi juaj u fshi me sukses
Ndodhi një gabim