Weiss
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Isdpfx Aov Sr Hzogmeik
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Isdpfx Aov Sr Hzogmeik
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Ofrues
Shënim: Regjistrohuni falas ose hyni, për të parë të gjitha informacionet.
I regjistruar që nga: 2012
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Këto njoftime mund t'ju interesojnë edhe ju.
Njoftim i vogël
Rimini
702 km
Makina për testimin e ngjeshjes / tërheqjes
ZwickRoell GmbHZ005TN
ZwickRoell GmbHZ005TN
Njoftim i vogël
Iserlohn
1 487 km
Aksi i 4-të CNC
NIKKENCNC -200
NIKKENCNC -200
Njoftim i vogël
Cestona
1 856 km
Ushqyes bar
LNSECO LOAD
LNSECO LOAD
Njoftim i vogël
Saarbrücken
1 372 km
Makinë matëse optike multisensore
MahrMS2VT Refurbished mit Garantie
MahrMS2VT Refurbished mit Garantie
Njoftim i vogël
Contamine-sur-Arve
1 242 km
Torno automatike me shumë gishta CNC
INDEXMS 32 C
INDEXMS 32 C
Njoftim i vogël
Zvicra
1 144 km
AGIECHARMILLES FORMULARI P350 – 2023 – makinë EDM me formë matëse
AGIECHARMILLES +GF+FORM P350
AGIECHARMILLES +GF+FORM P350
Njoftim i vogël
Strassberg
1 172 km
Makinë goditjeje automatike
BRUDERERBSTA 50 USL
BRUDERERBSTA 50 USL
Njoftim i vogël
Menslage
1 583 km
Enë ftohëse enë frigoriferike 40 këmbë (2019)
Ca l'ArenysKühlcontainer
Ca l'ArenysKühlcontainer
Njoftim i vogël
Contamine-sur-Arve
1 242 km
Qendra horizontale e përpunimit
QUASERHX404BP/15C
QUASERHX404BP/15C
Njoftim i vogël
Borken
1 562 km
Dhoma klimatike
VötschVC³ 4060
VötschVC³ 4060
Njoftimi juaj u fshi me sukses
Ndodhi një gabim