Kabineti i klimës me lagështi 34 litraWeiss
WKL 34/60 -60°C bis 150°C
Kabineti i klimës me lagështi 34 litra
Weiss
WKL 34/60 -60°C bis 150°C
Gjendje
I përdorur
Vendndodhje
Borken 

Fotot tregojnë
Shfaq hartën
Të dhëna për makinën
- Përshkrimi i makinës:
- Kabineti i klimës me lagështi 34 litra
- Prodhues:
- Weiss
- Gjendje:
- shumë mirë (i përdorur)
Çmimi & Vendndodhja
- Vendndodhje:
- Einsteinstraße 8a, 46325 Borken, DE

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A16211179
- Numri i referencës:
- 24134
- Përditësim:
- së fundmi më 15.11.2024
Përshkrim
White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
Nwjdpstr Dinofx Ahzsn
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
Nwjdpstr Dinofx Ahzsn
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Ofrues
Shënim: Regjistrohuni falas ose hyni, për të parë të gjitha informacionet.
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Njoftimi juaj u fshi me sukses
Ndodhi një gabim