Makinë për prodhimin e xhamit izolueslisec
Inspection Lightwall
Makinë për prodhimin e xhamit izolues
lisec
Inspection Lightwall
viti i prodhimit
2021
Gjendje
I përdorur
Vendndodhje
Maasmechelen 

Fotot tregojnë
Shfaq hartën
Të dhëna për makinën
- Përshkrimi i makinës:
- Makinë për prodhimin e xhamit izolues
- prodhues:
- lisec
- Model:
- Inspection Lightwall
- viti i prodhimit:
- 2021
- Gjendje:
- shumë mirë (i përdorur)
Çmimi & Vendndodhja
- Vendndodhje:
- Breitwaterstraat 22, 3630 Maasmechelen, BE
Telefononi
Detajet e ofertës
- ID e shpalljes:
- A18625526
- përditësim:
- së fundmi më 01.03.2025
Përshkrim
1. Switch on the wall and the electronics.
Do this by switching on the mean switch and the lightwall (on the back). So switch on the multimeters. See photos 1 and 2
Iiodpfx Agjv Ep U Aotsh
2. Adjust the upper and lower beam to the right cell height. Do this with 2 people. See photo 3
3. Check if there is no power on the cables coming from the power beam. Use the multimeters for this.
4. Connect the cells with the cables.
5. Check the cells with the protocol “Q3 quality finished cell”.
6. Use the right voltages for the different products. 24V for ddLC and 46V for scatter.
7. When doing the capacity measurement, turn the black switching knob from “power” to “R/C”. When done turn it back to “power”
8. When you have ddLC cells use the lightwall and the rotatable polar.
9. If you have scatter cells remove the lightwall and use the spotlight. For swtiching on/of this spotlight you can use the remote control. See photo 4.
10. When you are done, please use the mainswitch to power down, and switch of the used lights.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Do this by switching on the mean switch and the lightwall (on the back). So switch on the multimeters. See photos 1 and 2
Iiodpfx Agjv Ep U Aotsh
2. Adjust the upper and lower beam to the right cell height. Do this with 2 people. See photo 3
3. Check if there is no power on the cables coming from the power beam. Use the multimeters for this.
4. Connect the cells with the cables.
5. Check the cells with the protocol “Q3 quality finished cell”.
6. Use the right voltages for the different products. 24V for ddLC and 46V for scatter.
7. When doing the capacity measurement, turn the black switching knob from “power” to “R/C”. When done turn it back to “power”
8. When you have ddLC cells use the lightwall and the rotatable polar.
9. If you have scatter cells remove the lightwall and use the spotlight. For swtiching on/of this spotlight you can use the remote control. See photo 4.
10. When you are done, please use the mainswitch to power down, and switch of the used lights.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Ofrues
Shënim: Regjistrohuni falas ose hyni, për të parë të gjitha informacionet.
I regjistruar që nga: 2019
Dërgo kërkesë
Telefon & Faks
+32 89 53... njoftime
Njoftimi juaj u fshi me sukses
Ndodhi një gabim