HEIDEN Sistemi i Testimit të Futjes ES1.3 Instalim testimi me rrymë të drejtë me performancë të lartHEIDEN power
HTS14-500-1002
HEIDEN Sistemi i Testimit të Futjes ES1.3 Instalim testimi me rrymë të drejtë me performancë të lart
HEIDEN power
HTS14-500-1002
Gjendje
I përdorur
Vendndodhje
Borken 

Të dhëna bazë
- Përshkrimi i makinës:
- HEIDEN Sistemi i Testimit të Futjes ES1.3 Instalim testimi me rrymë të drejtë me performancë të lart
- Prodhues:
- HEIDEN power
- Model:
- HTS14-500-1002
- Gjendje:
- i përdorur
Çmimi & Vendndodhja
- Vendndodhje:
- Borken, Gjermania

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A23038881
- Numri i referencës:
- 25754
- Përditësim:
- së fundmi më 19.10.2026
Përshkrim
HEIDEN – COMPETENCE IN POWER
HEIDEN Infeed Test System ES1.3 High-performance DC test system 500 kW / 3x400V / 1000V 800A
Year of manufacture: 2015 · IGBT/PWM · HTS14 digital controller · industrial DC test system
Multi-part switchgear system for industrial testing and supply applications
with power, control, measurement and monitoring technology.
Technical data:
Manufacturer: HEIDEN
Model: Infeed Test System ES1.3
System type: 3870; Series: HTS14-500-1002
Device No.: 3870.550.01.400; Serial No.: 332732
Year of manufacture: 2015; Operation: DB (continuous operation)
Output rated power: 500 kW
Efficiency at rated load/voltage: 95 %
Power loss: 27 kW; Noise: max. 79 dB(A) @ 1 m
Input:
Mains: 3/PE/400 V AC ±10 %; 50 Hz ±6 %
Power consumption: 526 kVA; Power factor: >0.99
Maximum input current: 854 A @ 400 V
Itedpfjz Uc Sbox Abasn
Protective fuse: 3× gL/gG 1000 A
Cable: 3×185 mm²/phase; PE: 3×95 mm²
Output / Control:
DC: 10–1000 V adjustable; ±800 A, adjustable current limit
Rated power: 500 kW; Cable per pole: 3×150 mm²
Measurement accuracy/-resolution U/I: 0.1 % fs / 16 Bit ADC each
Control accuracy U/I: 0.1 % fs each
Static setpoint tolerance U: approx. max. ±0.1 % fs; I: max. ±0.1 % fs
Residual ripple U (ohmic load)/I: 0.1 % fs eff. each
Current rise time 10–90 % Iₙ: typ. ;2 ms (standard conditions)
Power / Control:
HEIDEN HTS14, LCD; Transistor rectifier, PWM, galvanically isolated; IGBT technology
IGBT power components: 3×1000 V DC (bill of materials ES1.3)
Digital IGBT controller/fast DC controller
Storage chokes: 3×1200 µH; thermally 270 A; saturation 400 A
DC contactors: 4× single-pole, coil 24 V; Filter charging unit
Cooling: forced air
Measurement / Safety:
LCD panel; Analog display 0–1000 V DC
Current transformers and shunts: 600 A/60 mV, class 0.5
Isometer IRDH275B-435; AGH150W up to 1100 V DC
Mushroom head PNOZmulti 2 with extensions (bill of materials)
Protection class 1 (EN 60950); IP20 (EN 60529)
Protective conductor current: ;5 % Iₙ, typ. 50 mA
Communication / Features:
CAN, Ethernet; CANopen (safety control)
Remote indicator relays; Control power supply 24 V DC/10 A (bill of materials)
Metal cabinets with ventilation; Operating, power, and control electronics
HTS14-LCD, Analog display, Control elements
Cable entry at the bottom; Door hinge on the right (standard)
Dimensions / Weights:
W×D×H: (1400+1200+1200)×1000×2000 mm
ES1.1: 1900 kg; ES1.2: 650 kg; ES1.3: 1050 kg
Total: approx. 3600 kg; RAL 7035
Wall distance min. 200 mm; Ceiling min. 300 mm
Operating conditions:
0 to +40 °C; RH 5–85 % without condensation
With cabinet heating up to 95 % RH without condensation
Installation height max. 1000 m above sea level at rated load; Air pressure min. 870 hPa
Restricted access; non-flammable base (e.g. concrete)
Pollution degree 2
Notes:
System data type 3870; Components/quantities according to the bill of materials. 500 kW applies to the entire system.
1000 V and 800 A are not confirmed to be available simultaneously. Cable cross-sections
apply to the documented installation conditions.
Scope of supply:
1× HEIDEN Infeed Test System with HTS14 and existing cabinet/power components as shown in the pictures.
Tools, machines and items not explicitly mentioned are not part of the sale.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
HEIDEN Infeed Test System ES1.3 High-performance DC test system 500 kW / 3x400V / 1000V 800A
Year of manufacture: 2015 · IGBT/PWM · HTS14 digital controller · industrial DC test system
Multi-part switchgear system for industrial testing and supply applications
with power, control, measurement and monitoring technology.
Technical data:
Manufacturer: HEIDEN
Model: Infeed Test System ES1.3
System type: 3870; Series: HTS14-500-1002
Device No.: 3870.550.01.400; Serial No.: 332732
Year of manufacture: 2015; Operation: DB (continuous operation)
Output rated power: 500 kW
Efficiency at rated load/voltage: 95 %
Power loss: 27 kW; Noise: max. 79 dB(A) @ 1 m
Input:
Mains: 3/PE/400 V AC ±10 %; 50 Hz ±6 %
Power consumption: 526 kVA; Power factor: >0.99
Maximum input current: 854 A @ 400 V
Itedpfjz Uc Sbox Abasn
Protective fuse: 3× gL/gG 1000 A
Cable: 3×185 mm²/phase; PE: 3×95 mm²
Output / Control:
DC: 10–1000 V adjustable; ±800 A, adjustable current limit
Rated power: 500 kW; Cable per pole: 3×150 mm²
Measurement accuracy/-resolution U/I: 0.1 % fs / 16 Bit ADC each
Control accuracy U/I: 0.1 % fs each
Static setpoint tolerance U: approx. max. ±0.1 % fs; I: max. ±0.1 % fs
Residual ripple U (ohmic load)/I: 0.1 % fs eff. each
Current rise time 10–90 % Iₙ: typ. ;2 ms (standard conditions)
Power / Control:
HEIDEN HTS14, LCD; Transistor rectifier, PWM, galvanically isolated; IGBT technology
IGBT power components: 3×1000 V DC (bill of materials ES1.3)
Digital IGBT controller/fast DC controller
Storage chokes: 3×1200 µH; thermally 270 A; saturation 400 A
DC contactors: 4× single-pole, coil 24 V; Filter charging unit
Cooling: forced air
Measurement / Safety:
LCD panel; Analog display 0–1000 V DC
Current transformers and shunts: 600 A/60 mV, class 0.5
Isometer IRDH275B-435; AGH150W up to 1100 V DC
Mushroom head PNOZmulti 2 with extensions (bill of materials)
Protection class 1 (EN 60950); IP20 (EN 60529)
Protective conductor current: ;5 % Iₙ, typ. 50 mA
Communication / Features:
CAN, Ethernet; CANopen (safety control)
Remote indicator relays; Control power supply 24 V DC/10 A (bill of materials)
Metal cabinets with ventilation; Operating, power, and control electronics
HTS14-LCD, Analog display, Control elements
Cable entry at the bottom; Door hinge on the right (standard)
Dimensions / Weights:
W×D×H: (1400+1200+1200)×1000×2000 mm
ES1.1: 1900 kg; ES1.2: 650 kg; ES1.3: 1050 kg
Total: approx. 3600 kg; RAL 7035
Wall distance min. 200 mm; Ceiling min. 300 mm
Operating conditions:
0 to +40 °C; RH 5–85 % without condensation
With cabinet heating up to 95 % RH without condensation
Installation height max. 1000 m above sea level at rated load; Air pressure min. 870 hPa
Restricted access; non-flammable base (e.g. concrete)
Pollution degree 2
Notes:
System data type 3870; Components/quantities according to the bill of materials. 500 kW applies to the entire system.
1000 V and 800 A are not confirmed to be available simultaneously. Cable cross-sections
apply to the documented installation conditions.
Scope of supply:
1× HEIDEN Infeed Test System with HTS14 and existing cabinet/power components as shown in the pictures.
Tools, machines and items not explicitly mentioned are not part of the sale.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Njoftimi juaj u fshi me sukses
Ndodhi një gabim

















