Përshkrim
Applied Biosystems ViiA7
Here we offer you an Applied Biosystems ViiA7.
Specifications:
Block change from instrument front in less than 1 minute; no secondary tooling required.
Supported applications Standard curve, comparative CT, genotyping, presence/absence, HRM, melting curve.
Temperature uniformity ±0.5 °C, within 30 seconds of reaching temperature set point
Chodpfslat Siox Af Sod
Run time ~35 min for 96/384-well blocks with Applied Biosystems® Fast Master Mix
Supported blocks and volumes 96-well standard (10-100 μl reactions)
96-well Fast (10-30 μl reactions) - 384-well (5-20 μl reactions)
TaqMan® Array Micro Fluidic Cards (~1 μl reactions).
Detectable sensitivity up to 1 copy - Excitation/detection wavelengths 6 Excitation (450-670 nm).
6 Emission (500-720 nm) - Dynamic Range Up to 9 logs linear dynamic range.
Resolution Detect as little as 1.5-fold changes in target quantities in a singleplex reaction
21 CFR p11 Enablement Security, audit, and e-signature features for instrument data
Automation Includes plate loading arm with barcode (sales, service, and support provided by Life Technologies)
Remote notification Notifies user via email when run is started, stopped or aborted
Data export format Fully configurable by user
Description:
Applied Biosystems Real-time PCR ViiA7.
Ideal for performing medium to high throughput real-time PCR.
Interchangeable blocks for 96-well, Fast 96-well and 384-well plates
as well as TaqMan Array Cards. Fast block change.
Touchscreen interface.
2x Ethernet port. 2x USB port.
1x RS 232 connector. 2x connection on the display.
Weight: 67 kg
Type: Applied Biosystems ViiA7
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, details are reserved!)
Further questions we can answer on the phone for you.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Here we offer you an Applied Biosystems ViiA7.
Specifications:
Block change from instrument front in less than 1 minute; no secondary tooling required.
Supported applications Standard curve, comparative CT, genotyping, presence/absence, HRM, melting curve.
Temperature uniformity ±0.5 °C, within 30 seconds of reaching temperature set point
Chodpfslat Siox Af Sod
Run time ~35 min for 96/384-well blocks with Applied Biosystems® Fast Master Mix
Supported blocks and volumes 96-well standard (10-100 μl reactions)
96-well Fast (10-30 μl reactions) - 384-well (5-20 μl reactions)
TaqMan® Array Micro Fluidic Cards (~1 μl reactions).
Detectable sensitivity up to 1 copy - Excitation/detection wavelengths 6 Excitation (450-670 nm).
6 Emission (500-720 nm) - Dynamic Range Up to 9 logs linear dynamic range.
Resolution Detect as little as 1.5-fold changes in target quantities in a singleplex reaction
21 CFR p11 Enablement Security, audit, and e-signature features for instrument data
Automation Includes plate loading arm with barcode (sales, service, and support provided by Life Technologies)
Remote notification Notifies user via email when run is started, stopped or aborted
Data export format Fully configurable by user
Description:
Applied Biosystems Real-time PCR ViiA7.
Ideal for performing medium to high throughput real-time PCR.
Interchangeable blocks for 96-well, Fast 96-well and 384-well plates
as well as TaqMan Array Cards. Fast block change.
Touchscreen interface.
2x Ethernet port. 2x USB port.
1x RS 232 connector. 2x connection on the display.
Weight: 67 kg
Type: Applied Biosystems ViiA7
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, details are reserved!)