Makinë koordinative matëseZeiss
O-Inspect 442 Zeiss Calypso
Makinë koordinative matëse
Zeiss
O-Inspect 442 Zeiss Calypso
viti i prodhimit
2012
Gjendje
I përdorur
Vendndodhje
Saarbrücken 

Fotot tregojnë
Shfaq hartën
Të dhëna për makinën
- Përshkrimi i makinës:
- Makinë koordinative matëse
- Prodhues:
- Zeiss
- Viti i prodhimit:
- 2012
- Gjendje:
- mirë (i përdorur)
- Funksionalitet:
- plotësisht funksionale
Çmimi & Vendndodhja
- Vendndodhje:
- An den Ziegelhütten 19-21, 66127 Saarbrücken, Deutschland

Telefononi
Detaje teknike
- Gama matëse boshti X:
- 400 mm
- Shtrirja e matjes së boshtit Y:
- 400 mm
- Gama e matjes së boshtit Z:
- 200 mm
- Distanca lëvizëse e boshtit X:
- 400 mm
- Distanca e lëvizjes së boshtit Y:
- 400 mm
- Distanca e lëvizjes së boshtit Z:
- 200 mm
- Tensioni hyrës:
- 230 V
- Pajisje:
- Pllakë tip e disponueshme, ndriçim
Detajet e ofertës
- ID e shpalljes:
- A17230982
- Përditësim:
- së fundmi më 27.10.2025
Përshkrim
Year of manufacture: 2012
Tactile:
Vast XXT
E0 X/Y (1D) in [μm] at 20 ±2 °C 1.7 + L/250
E0 XY (2D) in [μm] at 20 ±2 °C 1.7 + L/250
E0 (3D) in [μm] at 20 ±2 °C 1.9 + L/250
Fpedpfxouq Nfhs Adkjp
Scanning probing deviation
MPE according to ISO 10360-4:2000 THP at 2.7 [μm]
Single probe probing deviation form
MPE according to ISO 10360-5:2010
PFTU 1.9 [μm]
Camera system:
Zeiss Discovery 12
EB X/Y (1D) 5) in [μm] at 20 ±2 °C 1.7 + L/250
EB XY (2D) 5) in [μm] at 20 ±2 °C 1.7 + L/250
Probe deviation MPE according to ISO 10360-7:2011
PF2D 5) 1.7 [μm]
Probe deviation of the image processing system
MPE according to ISO 10360-7:2011
PFV2D 5) 1.2 [μm]
Possible services: delivery, commissioning
Tactile:
Vast XXT
E0 X/Y (1D) in [μm] at 20 ±2 °C 1.7 + L/250
E0 XY (2D) in [μm] at 20 ±2 °C 1.7 + L/250
E0 (3D) in [μm] at 20 ±2 °C 1.9 + L/250
Fpedpfxouq Nfhs Adkjp
Scanning probing deviation
MPE according to ISO 10360-4:2000 THP at 2.7 [μm]
Single probe probing deviation form
MPE according to ISO 10360-5:2010
PFTU 1.9 [μm]
Camera system:
Zeiss Discovery 12
EB X/Y (1D) 5) in [μm] at 20 ±2 °C 1.7 + L/250
EB XY (2D) 5) in [μm] at 20 ±2 °C 1.7 + L/250
Probe deviation MPE according to ISO 10360-7:2011
PF2D 5) 1.7 [μm]
Probe deviation of the image processing system
MPE according to ISO 10360-7:2011
PFV2D 5) 1.2 [μm]
Possible services: delivery, commissioning
Ofrues
Shënim: Regjistrohuni falas ose hyni, për të parë të gjitha informacionet.
I regjistruar që nga: 2016
Dërgo kërkesë
Telefon & Faks
+49 6898 ... njoftime
Njoftimi juaj u fshi me sukses
Ndodhi një gabim