Kuti klimatike me lagështi -70°C deri në 180°Weiss
WK11-600/70/5
Kuti klimatike me lagështi -70°C deri në 180°
Weiss
WK11-600/70/5
Gjendje
I përdorur
Vendndodhje
Borken 

Fotot tregojnë
Shfaq hartën
Të dhëna për makinën
- Përshkrimi i makinës:
- Kuti klimatike me lagështi -70°C deri në 180°
- Prodhues:
- Weiss
- Model:
- WK11-600/70/5
- Gjendje:
- shumë mirë (i përdorur)
Çmimi & Vendndodhja
- Vendndodhje:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A21144637
- Numri i referencës:
- 25022
- Përditësim:
- së fundmi më 02.02.2026
Përshkrim
Weiss
Type: WK11 - 600/70/5
Weiss Climate Chamber Water-Cooled
The Weiss climate chamber WK11-600/70/5 with approximately 600 liters usable volume is suitable for temperature and humidity testing, as well as for the conditioning of samples and materials in a range from −70 °C to +180 °C.
Simcon/32 - Net controller
Technical Data:
Test chamber designation: WK11-600/70/5
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 800 mm
Internal dimensions:
Ledpfeyglb Sjx Ab Iohd
Height 950 mm, Width 800 mm, Depth 800 mm
Feedthroughs:
2x R1 NW 125 mm ∅
1x L1 NW 50 mm ∅
Test chamber volume: approx. 600 liters
Temperature Test Data:
Temperature range: -70 °C to +180°C
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.5 K
Spatial temperature deviations: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 6 K/min
Cooling: 6 K/min
Heat compensation:
At +20 °C: 5000 W
At -20 °C: 5000 W
Climate Test Data:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% r. H.
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.3 K
Spatial temperature deviations: ±0.5 to ±1 K
Temperature gradient: 1 to 2
Humidity fluctuation (temporal, center of usable space): ±1 to ±3% r. H.
Heat compensation: 500 W
3/N/PE AC 400V ±10% 50Hz
Rated power: 16.5 kW
Rated current: 29 A
Main fuse (to be provided by customer): 32 A slow-blow
Permissible test material weight:
Total load of racks: 80 kg
Test chamber floor: 80 kg, Insert rack: 40 kg
Weight: 675 kg
Refrigerants: R452A / R23
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, please note the following information:
The following points are completed on our offered chambers beforehand:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical specifications subject to change and errors excepted!)
We are happy to answer any further questions over the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Type: WK11 - 600/70/5
Weiss Climate Chamber Water-Cooled
The Weiss climate chamber WK11-600/70/5 with approximately 600 liters usable volume is suitable for temperature and humidity testing, as well as for the conditioning of samples and materials in a range from −70 °C to +180 °C.
Simcon/32 - Net controller
Technical Data:
Test chamber designation: WK11-600/70/5
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 800 mm
Internal dimensions:
Ledpfeyglb Sjx Ab Iohd
Height 950 mm, Width 800 mm, Depth 800 mm
Feedthroughs:
2x R1 NW 125 mm ∅
1x L1 NW 50 mm ∅
Test chamber volume: approx. 600 liters
Temperature Test Data:
Temperature range: -70 °C to +180°C
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.5 K
Spatial temperature deviations: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 6 K/min
Cooling: 6 K/min
Heat compensation:
At +20 °C: 5000 W
At -20 °C: 5000 W
Climate Test Data:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% r. H.
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.3 K
Spatial temperature deviations: ±0.5 to ±1 K
Temperature gradient: 1 to 2
Humidity fluctuation (temporal, center of usable space): ±1 to ±3% r. H.
Heat compensation: 500 W
3/N/PE AC 400V ±10% 50Hz
Rated power: 16.5 kW
Rated current: 29 A
Main fuse (to be provided by customer): 32 A slow-blow
Permissible test material weight:
Total load of racks: 80 kg
Test chamber floor: 80 kg, Insert rack: 40 kg
Weight: 675 kg
Refrigerants: R452A / R23
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, please note the following information:
The following points are completed on our offered chambers beforehand:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical specifications subject to change and errors excepted!)
We are happy to answer any further questions over the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Këto njoftime mund t'ju interesojnë edhe ju.
Njoftim i vogël
Borken
1 562 km
Kabineti i klimës 335 litra
WeissWK-340/70 -70 °C bis +180 °C
WeissWK-340/70 -70 °C bis +180 °C
Njoftimi juaj u fshi me sukses
Ndodhi një gabim