Dollap testimi për goditje termikeWeiss
130 Liter TS 130 *
Dollap testimi për goditje termike
Weiss
130 Liter TS 130 *
Gjendje
I përdorur
Vendndodhje
Borken 

Të dhëna për makinën
- Përshkrimi i makinës:
- Dollap testimi për goditje termike
- Prodhues:
- Weiss
- Model:
- 130 Liter TS 130 *
- Gjendje:
- shumë mirë (i përdorur)
Çmimi & Vendndodhja
- Vendndodhje:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A22148217
- Numri i referencës:
- 23475
- Përditësim:
- së fundmi më 18.06.2026
Përshkrim
Here we offer you a temperature shock testing chamber.
Weiss temperature shock testing chamber, air-cooled
Kjdpfx Aezd Sd Hof Aelu
Specification:
Temperature range, warm chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Changeover time, warm/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): height 450 mm, width 500 mm, depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Weiss temperature shock testing chamber, air-cooled
Kjdpfx Aezd Sd Hof Aelu
Specification:
Temperature range, warm chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Changeover time, warm/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): height 450 mm, width 500 mm, depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.