Përshkrim
HPLC Waters
The system consists of these modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
Pedpfsvcnpajx Agijrd
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
The system consists of these modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
Pedpfsvcnpajx Agijrd
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Ofrues
Shënim: Regjistrohuni falas ose hyni, për të parë të gjitha informacionet.
I regjistruar që nga: 2012
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Njoftimi juaj u fshi me sukses
Ndodhi një gabim