Dhoma e testimit të klimës 335 litra me lagështiVötsch
VCS 7034-5 -70°C bis +180°C
Dhoma e testimit të klimës 335 litra me lagështi
Vötsch
VCS 7034-5 -70°C bis +180°C
Gjendje
I përdorur
Vendndodhje
Borken 

Fotot tregojnë
Shfaq hartën
Të dhëna për makinën
- Përshkrimi i makinës:
- Dhoma e testimit të klimës 335 litra me lagështi
- Prodhues:
- Vötsch
- Gjendje:
- mirë (i përdorur)
Çmimi & Vendndodhja
- Vendndodhje:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A20090755
- Numri i referencës:
- 24810
- Përditësim:
- së fundmi më 29.09.2025
Përshkrim
Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test chamber volume: 335 litres
Performance for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Isdpfoxgd Rdsx Agmsik
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Performance for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50 % RH and +95°C / 50 % RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Nominal power: 10 kW
Nominal current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R-404A / R-23
For your safety as a buyer, please note the following information!
The following steps are carried out on all our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
Feel free to contact us by phone for any further questions.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test chamber volume: 335 litres
Performance for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Isdpfoxgd Rdsx Agmsik
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Performance for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50 % RH and +95°C / 50 % RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Nominal power: 10 kW
Nominal current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R-404A / R-23
For your safety as a buyer, please note the following information!
The following steps are carried out on all our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
Feel free to contact us by phone for any further questions.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Ofrues
Shënim: Regjistrohuni falas ose hyni, për të parë të gjitha informacionet.
I regjistruar që nga: 2012
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Këto njoftime mund t'ju interesojnë edhe ju.
Njoftim i vogël
Borken
1 562 km
Dhoma e testimit të klimës 335 litra me lagështi
VötschVCS³ 7034-5 -70°C bis +180°C
VötschVCS³ 7034-5 -70°C bis +180°C
Njoftim i vogël
Borken
1 562 km
Dhoma klimatike me lagështi, 335 litra
VötschVC³ 7034 -70°C bis +180°C
VötschVC³ 7034 -70°C bis +180°C
Njoftim i vogël
Borken
1 562 km
Dhoma e testimit të klimës 335 litra me lagështi
VötschVCS 7034-5 -70°C bis +180°C
VötschVCS 7034-5 -70°C bis +180°C
Njoftim i vogël
Borken
1 562 km
Dhoma e testimit të klimës 335 litra me lagështi
VötschVCS 7034-5 -70°C bis +180°C
VötschVCS 7034-5 -70°C bis +180°C
Njoftim i vogël
Borken
1 562 km
Dhoma e testimit të klimës me lagështi 34 litra
VötschVCL 7003 -70°C bis +180°C
VötschVCL 7003 -70°C bis +180°C
Njoftim i vogël
Amstetten
879 km
Dhoma e testimit të klimës Weiss SB11/300/40 -40..
WEISSSB11/300/40
WEISSSB11/300/40
Njoftim i vogël
Borken
1 562 km
Dhoma e testit të klimës 600 litra
WeissWK3-600/70 -70°C bis +180°C
WeissWK3-600/70 -70°C bis +180°C
Njoftim i vogël
Borken
1 571 km
Dhoma e provës klimatike
EspecPR-3KP
EspecPR-3KP
Njoftimi juaj u fshi me sukses
Ndodhi një gabim