Dollapi klimatik testues Vötsch VCS³ 7034-5 -70°C deri në +180°C me lagështi, kapacitet 335 litraVötsch
VCS³ 7034-5
Dollapi klimatik testues Vötsch VCS³ 7034-5 -70°C deri në +180°C me lagështi, kapacitet 335 litra
Vötsch
VCS³ 7034-5
Gjendje
I përdorur
Vendndodhje
Borken 

Të dhëna bazë
- Përshkrimi i makinës:
- Dollapi klimatik testues Vötsch VCS³ 7034-5 -70°C deri në +180°C me lagështi, kapacitet 335 litra
- Prodhues:
- Vötsch
- Model:
- VCS³ 7034-5
- Gjendje:
- i përdorur
Çmimi & Vendndodhja
- Vendndodhje:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A22270587
- Numri i referencës:
- 24918
- Përditësim:
- së fundmi më 15.10.2026
Përshkrim
Vötsch
Type: VCS³ 7034-5
Vötsch Climate Testing Chamber, Water-Cooled
With a temperature change rate of 5 K/min
Data for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.1 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ± 0.1 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 870 x Depth 1700 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 765 x Height 750 (mm)
Test chamber volume: approx. 335 liters
Side opening: 50 mm
Side opening: 125 mm
Lsdpfx Ajziyx Nscdshn
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10 %, 50 Hz
Rated power: 9 kW, Rated current: 20 A
Fuse, on customer's side: 63 A slow-blow
Refrigerant: R404A/R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Type: VCS³ 7034-5
Vötsch Climate Testing Chamber, Water-Cooled
With a temperature change rate of 5 K/min
Data for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.1 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ± 0.1 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 870 x Depth 1700 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 765 x Height 750 (mm)
Test chamber volume: approx. 335 liters
Side opening: 50 mm
Side opening: 125 mm
Lsdpfx Ajziyx Nscdshn
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10 %, 50 Hz
Rated power: 9 kW, Rated current: 20 A
Fuse, on customer's side: 63 A slow-blow
Refrigerant: R404A/R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Këto njoftime mund t'ju interesojnë edhe ju.
I suksesshëm
Mesazhi juaj u dërgua.
Njoftim i vogël
Borken
1 562 km
Vötsch VCS³ 7034-5 Kabinë klimatike për testim, Kabinë për testim të temperaturës -70°C deri +180°C,
VötschVCS³ 7034-5
VötschVCS³ 7034-5
I suksesshëm
Mesazhi juaj u dërgua.
Njoftim i vogël
Borken
1 562 km
Viti i prodhimit 2018, 600 litra
CTS TemperaturprüfschrankT-70/600 -70 bis +210°C
CTS TemperaturprüfschrankT-70/600 -70 bis +210°C
I suksesshëm
Mesazhi juaj u dërgua.
Njoftim i vogël
Borken
1 562 km
Vötsch VCS³ 7034-5 Dhomë testimi klimatike -70 deri +180 °C Lagështi 335 litra me lagështi, viti i p
Heraeus VötschVCS³ 7034-5
Heraeus VötschVCS³ 7034-5
I suksesshëm
Mesazhi juaj u dërgua.
Njoftim i vogël
Borken
1 562 km
Vötsch VCS³ 7034-5 Kabinë klimatike për testim, Kabinë për testim të temperaturës -70°C deri +180°C,
VötschVCS³ 7034-5
VötschVCS³ 7034-5
Njoftimi juaj u fshi me sukses
Ndodhi një gabim