Dhoma për testimin e temperaturës -75 deri në +150 °CFeutron
3416/16-Ex TPK 200
Dhoma për testimin e temperaturës -75 deri në +150 °C
Feutron
3416/16-Ex TPK 200
Gjendje
I përdorur
Vendndodhje
Borken 

Të dhëna bazë
- Përshkrimi i makinës:
- Dhoma për testimin e temperaturës -75 deri në +150 °C
- Prodhues:
- Feutron
- Model:
- 3416/16-Ex TPK 200
- Gjendje:
- shumë mirë (i përdorur)
Çmimi & Vendndodhja
- Vendndodhje:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A22849265
- Numri i referencës:
- 25681
- Përditësim:
- së fundmi më 01.10.2026
Përshkrim
eutron 3416/16-Ex TPK 200 Temperature Test Chamber
Manufacturer: Feutron Klimasimulation GmbH
Type: 3416/16-Ex
Series: TPK 200
Year of Construction: 2006
Machine Type: Temperature Test Chamber / Climate Simulation Chamber
Test Chamber Volume: 280 liters
For sale is a used Feutron 3416/16-Ex temperature test chamber with programmable control.
The system was developed for professional temperature tests,
environmental simulation, and material and component testing,
and is particularly suitable for testing laboratories, electronics,
research and development, and quality assurance.
Technical Data:
Model: 3416/16-Ex
Series: TPK 200
Year of Construction: 2006
Operating Hours: 59,655 h
Test Chamber Volume: 280 liters
Temperature Range: -75 °C to +150 °C
Blsdpfx Abez Hl Dvswen
Temperature Deviation (over time): ≤ ±0.5 K
Temperature Change (Heating): up to approximately 3.0 K/min on average
Temperature Change (Cooling): up to approximately 1.0 K/min on average
Test Chamber Material: Stainless steel, material no. 1.4301
Test Chamber Insulation: CFC-free multi-layer insulation
Refrigeration System:
Design: Water-cooled, semi-hermetic cascade system
Refrigerant 1: R507
Refrigerant Quantity: 2.5 kg
Refrigerant 2: R23
Refrigerant Quantity: 0.5 kg
Continuous Sound Pressure Level: approximately 67 dB(A)
Cooling Water:
Cooling Water Pressure: min. approximately 2.0 bar / max. 6.0 bar
Max. Cooling Water Temperature (Inlet): approximately 18 °C
Cooling Water Temperature (Outlet): approximately 30 °C
Average Cooling Water Consumption: approximately 0.3 m³/h
Electrical Data:
Supply: 400 V / 3/N/PE AC / 50 Hz
Power Plug: CEE 5-pin, 16 A
Max. Simultaneous Power Consumption: 5.6 kW
Fuse Rating: 3 × 16 A, characteristic C
Protection Class: IP20
Dimensions:
External Dimensions (W × D × H): approximately 1,500 × 1,075 × 2,140 mm
Min. Installation Dimensions: approximately 1,500 × 995 × 1,960 mm
Installation Dimensions with Doors Open (W × D × H): approximately 2,400 × 1,990 × 2,140 mm
Weight: approximately 680 kg
Equipment:
Programmable Feutron Controller
LCD Display
Program and manual operation
Up to 20 programs can be stored
RS-232 interface
3 stainless steel grids
Test chamber lighting
Observation window
1 × feedthrough Ø 75 mm with cover cap
2 × feedthrough Ø 75 mm on the side
1 × feedthrough Ø 100 mm on the side
Compressed air connection
Cooling water supply and return
Additional temperature controller
Accessories according to images
Transport Data:
Device (W × D × H): approximately 1,500 × 1,075 × 2,140 mm
Weight: approximately 680 kg
Min. Installation Dimensions after Dismantling Corresponding Components: approximately 1,500 × 995 × 1,960 mm
Condition:
Used
Device starts up.
Controller and display are active.
Optical condition according to images.
Scope of Delivery:
Feutron 3416/16-Ex TPK 200 Temperature Test Chamber
3 stainless steel grids
Fan / Accessories according to images
Documentation according to images
Availability: by arrangement.
Scope of delivery as shown in the images.
Subject to change, errors and prior sale.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Manufacturer: Feutron Klimasimulation GmbH
Type: 3416/16-Ex
Series: TPK 200
Year of Construction: 2006
Machine Type: Temperature Test Chamber / Climate Simulation Chamber
Test Chamber Volume: 280 liters
For sale is a used Feutron 3416/16-Ex temperature test chamber with programmable control.
The system was developed for professional temperature tests,
environmental simulation, and material and component testing,
and is particularly suitable for testing laboratories, electronics,
research and development, and quality assurance.
Technical Data:
Model: 3416/16-Ex
Series: TPK 200
Year of Construction: 2006
Operating Hours: 59,655 h
Test Chamber Volume: 280 liters
Temperature Range: -75 °C to +150 °C
Blsdpfx Abez Hl Dvswen
Temperature Deviation (over time): ≤ ±0.5 K
Temperature Change (Heating): up to approximately 3.0 K/min on average
Temperature Change (Cooling): up to approximately 1.0 K/min on average
Test Chamber Material: Stainless steel, material no. 1.4301
Test Chamber Insulation: CFC-free multi-layer insulation
Refrigeration System:
Design: Water-cooled, semi-hermetic cascade system
Refrigerant 1: R507
Refrigerant Quantity: 2.5 kg
Refrigerant 2: R23
Refrigerant Quantity: 0.5 kg
Continuous Sound Pressure Level: approximately 67 dB(A)
Cooling Water:
Cooling Water Pressure: min. approximately 2.0 bar / max. 6.0 bar
Max. Cooling Water Temperature (Inlet): approximately 18 °C
Cooling Water Temperature (Outlet): approximately 30 °C
Average Cooling Water Consumption: approximately 0.3 m³/h
Electrical Data:
Supply: 400 V / 3/N/PE AC / 50 Hz
Power Plug: CEE 5-pin, 16 A
Max. Simultaneous Power Consumption: 5.6 kW
Fuse Rating: 3 × 16 A, characteristic C
Protection Class: IP20
Dimensions:
External Dimensions (W × D × H): approximately 1,500 × 1,075 × 2,140 mm
Min. Installation Dimensions: approximately 1,500 × 995 × 1,960 mm
Installation Dimensions with Doors Open (W × D × H): approximately 2,400 × 1,990 × 2,140 mm
Weight: approximately 680 kg
Equipment:
Programmable Feutron Controller
LCD Display
Program and manual operation
Up to 20 programs can be stored
RS-232 interface
3 stainless steel grids
Test chamber lighting
Observation window
1 × feedthrough Ø 75 mm with cover cap
2 × feedthrough Ø 75 mm on the side
1 × feedthrough Ø 100 mm on the side
Compressed air connection
Cooling water supply and return
Additional temperature controller
Accessories according to images
Transport Data:
Device (W × D × H): approximately 1,500 × 1,075 × 2,140 mm
Weight: approximately 680 kg
Min. Installation Dimensions after Dismantling Corresponding Components: approximately 1,500 × 995 × 1,960 mm
Condition:
Used
Device starts up.
Controller and display are active.
Optical condition according to images.
Scope of Delivery:
Feutron 3416/16-Ex TPK 200 Temperature Test Chamber
3 stainless steel grids
Fan / Accessories according to images
Documentation according to images
Availability: by arrangement.
Scope of delivery as shown in the images.
Subject to change, errors and prior sale.
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Këto njoftime mund t'ju interesojnë edhe ju.
I suksesshëm
Mesazhi juaj u dërgua.
Njoftim i vogël
Borken
1 562 km
Dollap testimi klimatik -42 deri në +190°C
MemmertCTC 256 256 Liter
MemmertCTC 256 256 Liter
I suksesshëm
Mesazhi juaj u dërgua.
Njoftim i vogël
Żychlin
1 235 km
Dhoma klimatike Memmert ICH 260
MemmertICH 260
MemmertICH 260
Njoftimi juaj u fshi me sukses
Ndodhi një gabim