Kabineti i testit të temperaturës është i mbrojturCTS
T-30/950 Ex/I
Kabineti i testit të temperaturës është i mbrojtur
CTS
T-30/950 Ex/I
viti i prodhimit
2011
Gjendje
I përdorur
Vendndodhje
Borken 

Fotot tregojnë
Shfaq hartën
Të dhëna për makinën
- Përshkrimi i makinës:
- Kabineti i testit të temperaturës është i mbrojtur
- Prodhues:
- CTS
- Model:
- T-30/950 Ex/I
- Viti i prodhimit:
- 2011
- Gjendje:
- shumë mirë (i përdorur)
Çmimi & Vendndodhja
- Vendndodhje:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Telefononi
Detajet e ofertës
- ID e shpalljes:
- A7538378
- Numri i referencës:
- 23117
- Përditësim:
- së fundmi më 27.06.2025
Përshkrim
CTS
Type: T-30/950 Ex/I
Fgjdpfx Aoihb Amsg Hek
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Type: T-30/950 Ex/I
Fgjdpfx Aoihb Amsg Hek
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Njoftimi është përkthyer automatikisht. Mund të ketë gabime në përkthim.
Ofrues
Shënim: Regjistrohuni falas ose hyni, për të parë të gjitha informacionet.
I regjistruar që nga: 2012
Dërgo kërkesë
Telefon & Faks
+49 2861 ... njoftime
Këto njoftime mund t'ju interesojnë edhe ju.
njoftim i vogël
Hochdorf
1 187 km
Njësia e ftohjes së temperaturës (TCU)
SingleCompact WK3-160-9-50 (IM160F)
SingleCompact WK3-160-9-50 (IM160F)
njoftim i vogël
Berlin
1 362 km
Kondensator boshtor
Güntner AGGVH 100.2A/2x3-J(D)
Güntner AGGVH 100.2A/2x3-J(D)
njoftim i vogël
Tata
737 km
Kondensator i ftohësit të lëngshëm
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
njoftim i vogël
Forst
1 271 km
Depozita tampon 100 m³, 3 bar, e izoluar
njoftim i vogël
Delmenhorst
1 579 km
Ruajtja e tamponit të rezervuarit me presion 1000L
10539
10539
njoftim i vogël
Schmölln
1 238 km
Dhomë të ftohtë
Dresdner Kühlanlagenbau
Dresdner Kühlanlagenbau
njoftim i vogël
Niedźwiedź
941 km
Njësi kompresori me dy faza
BitzerS6G-25.2Y (x4)
BitzerS6G-25.2Y (x4)
njoftim i vogël
Borken
1 562 km
Dhoma e testimit të klimës me lagështi 1000 litra
CTSC-40/1000 -40°C bis +180°C
CTSC-40/1000 -40°C bis +180°C
njoftim i vogël
Nattheim
1 147 km
Sharrë paneli në këmbë
Holz-Her1255
Holz-Her1255
njoftim i vogël
Wiefelstede
1 622 km
Sistemi i ventilimit
HeimerWK-61
HeimerWK-61
Njoftimi juaj u fshi me sukses
Ndodhi një gabim